rodiyer.idv.tw 拉里拉雜
rodiyer.idv.tw 拉里拉雜
| 問 | Effluent decontamination systems are categorized into heat-based and chemical-based systems. Their processing methods can be categorized into batch and continuous processes. |
| ✓ | 〇 |
| ╳ | |
| www.rodiyer.com | |
| 問 | For chemical disinfectants in use, laboratories should refer only to manufacturer's instructions. Efficacy testing is not necessary. |
| 〇 | |
| ✓ | ╳ |
| www.rodiyer.com | |
| 問 | Verification frequency of autoclaves is determined through LRA. |
| ✓ | 〇 |
| ╳ | |
| www.rodiyer.com | |
| 問 | Which of the following statements regarding the decontamination of surfaces is correct? |
| Establish SOPs for handling spills of infectious substances in laboratories. | |
| Spill buckets should always be available in laboratories. | |
| Training should be carried out regularly. | |
| Drills should be carried out regularly. All personnel should be familiar with the procedures. | |
| ✓ | All of the above. |
| www.rodiyer.com | |
| 問 | Which of the following statements regarding biological indicators is correct? |
| Indicate that the sterilization process is effective. | |
| Spores of Geobacillus stearothermophilus are commonly used as biological indicators. | |
| Suitable for both autoclave and hydrogen peroxide sterilization. | |
| Positive control from same lot number as processed biological indicators must be available for comparison. | |
| ✓ | All of the above. |
| www.rodiyer.com | |
| 問 | Decontamination technologies and processes are to be validated prior to implementation of the procedure to ensure their effectiveness against specific pathogens or toxins being handled. Under which of...(以下略) |
| Prior to initial use. | |
| New pathogens are introduced. | |
| Significant changes are implemented. | |
| ✓ | All of the above. |
| www.rodiyer.com | |
| 問 | Which of the following options is a process that completely eliminates all living microorganisms, including bacterial spores. The probability of a microorganism surviving a sterilization process is co...(以下略) |
| ✓ | Sterilization |
| Disinfection | |
| Decontamination | |
| None of the above | |
| www.rodiyer.com | |
| 問 | Which of the following values is the target value for viable spores reduction when performing decontamination? |
| 8-log10 (99.999999%) | |
| ✓ | 6-log10 (99.9999%) |
| 4-log10 (99.99%) | |
| 2-log10 (99%) | |
| None of the above | |
| www.rodiyer.com | |
| 問 | QACs are effective against vegetative bacteria and enveloped viruses, and available with built-in detergent action. |
| ✓ | 〇 |
| ╳ | |
| www.rodiyer.com | |
| 問 | Disinfectant effectiveness depends on the active ingredients as well as on identity and concentration of other ingredients in the formulation. |
| ✓ | 〇 |
| ╳ |
沒有留言: