問 BSCs are open workspaces designed to protect laboratory personnelthrough the use of directional air flow and High Efficiency Particulate Air filters.
〇
✓ ╳
www.rodiyer.com
問 Key considerations for selecting appropriate PPE include
Characteristics of the biological agent
Type of work being carried out
Availability of national regulations
✓ All of the above are correct
www.rodiyer.com
問 Essential biosafety equipment do not include
PPE
Autoclave
✓ Bench
Biological safety cabinet
www.rodiyer.com
問 HEPA filter performance of a minimum efficiency of 99.97% should be used
〇
✓ ╳
www.rodiyer.com
問 Things to avoid when using a BSC
Use open flame
Rapid arm movements
Block the grills
✓ All of the above mentioned
www.rodiyer.com
問 Which of the following description of the autoclave is incorrect?
Do not overload the autoclave
Use separate autoclaves for ‘clean’ and ‘dirty’ loads
✓ No need to monitor autoclave sterization regularly
Do not operate overnight
www.rodiyer.com
問 Different types of glove may be needed for different tasks or with other occupational hazards, such as heat or sharps.
✓ 〇
╳
www.rodiyer.com
問 Air particles are caught by HEPA through which mechanism?
Diffusion
Interception
Impaction
✓ All of the above are correct
www.rodiyer.com
問 PPE is used only in BSL-2,3 and 4 biological laboratories
〇
✓ ╳
www.rodiyer.com
問 Gloves should always be inspected before use to check that they are intact.
✓ 〇
╳
www.rodiyer.com
問 When use combinations of PPE needs to consider complementing one another
✓ 〇
╳
www.rodiyer.com
問 Which description is incorrect?
Minimum distance between BSC and door is 1.1 m
✓ Minimum distance between 2 side-by-side BSCs is 1 m
2 BSCs put in the opposite site along the wall, the minimum space between 2 persons is 3.1 meters
The airflow curtain that helps provide protection when working in a BSC is fragile
www.rodiyer.com
問 Work surfaces and interior walls need to be disinfected only after each use
〇
✓ ╳
www.rodiyer.com
問 The minimum space between BSC and door is 1.1 meter and the same distance between 2 side-by side BSCs.
✓ 〇
╳
www.rodiyer.com
問 Which level of biosafety laboratory required to use PPE?
BSL-1
BSL-2
BSL-3
✓ All of the above are correct
www.rodiyer.com
問 Autoclave sterilization condiction?
✓ 121°C for 60 minutes
100°C for 60 minutes
85°C for 60 minutes
121°C for 15 minutes
www.rodiyer.com
問 UV light is not recommended to be used in BSCs
✓ 〇
╳
www.rodiyer.com
問 If an autoclave used for sterilize the infectious substances, Its exhaust should be filtered through a filter with membrane size of
0.1 micron
✓ 0.2 micron
0.3 micron
0.4 micron
www.rodiyer.com
問 Autoclaving is the most dependable method of sterilizing laboratory equipment and decontaminating biohazard wastes.
✓ 〇
╳
www.rodiyer.com
問 Which form of PPE is one of the most critical and easily implemented ?
Footware
✓ Eye protection
Lab coat
Respiratory protection
www.rodiyer.com
問 After moving a BSC within the laboratory, it is not nessersary to certified the BSC.
〇
✓ ╳
www.rodiyer.com
問 Which class of BSC can not protect ptoducts?
Class III
✓ Class I
Class II A1
Class II B1
www.rodiyer.com
問 When infectious materials are sterilized, exhaust of an autoclave should be filtered through a filter with 0.2 micron membrane
✓ 〇
╳
www.rodiyer.com
問 Which class of BSC do not have HEPA filtered supply air?
Class II
ClassIII
✓ Class I
Class II B1
www.rodiyer.com
問 The proper type of PPE must be chosen and personnel must be trained in its proper use and know how to detect any faults
✓ 〇
╳
www.rodiyer.com
問 Which one is not a key consideration for selecting PPE?
Volumes and concentrations of the biological agent
✓ Color
Other PPE being worn
Individual needs of the laboratory personnel
www.rodiyer.com
問 Which of the following descriptions of the functions of a biological safety cabinet is incorrect?
Air in the Class I, Class II B2, and Class III BSC is 100% exhausted
There are 3 classes of BSC
✓ None of BSC can be applied to handle volatile toxic chemicals
Class II A1 and A2 BSCs can be a thimble connected
www.rodiyer.com
問 The laboratory director should ensure that the adequate equipment is provided and used properly.
✓ 〇
╳
www.rodiyer.com
問 Which PPE is not a core requirement?
✓ Respiratory protection
Gloves
Lab coat
Footware
www.rodiyer.com
問 All classes of BSC can protect personnel, enviroment and product
〇
✓ ╳